Formulas

Common respiratory care equations, with units and worked examples.

26 entries · 6 categories

Oxygenation

Oxygen pressure, gas exchange, and arterial oxygen content.

Relates arterial oxygen pressure to the oxygen being delivered.

Use FiO₂ as a fraction. The ratio alone does not establish an ARDS diagnosis.

Units & worked example
PaO₂
Arterial oxygen pressure, mmHg.
FiO₂
Inspired oxygen fraction: 40% = 0.40.

PaO₂ 80 mmHg on FiO₂ 0.40: 80 / 0.40 = 200 mmHg.

Estimates alveolar oxygen pressure using the abbreviated equation.

This is an approximation. Use the appropriate barometric pressure at altitude; assumed R and high FiO₂ can affect accuracy.

Units & worked example
PAO₂
Alveolar oxygen pressure, mmHg; uppercase A means alveolar.
PB
Barometric pressure, mmHg; about 760 at sea level.
PH₂O
Water vapor pressure: 47 mmHg at 37°C.
PaCO₂
Arterial CO₂ pressure, mmHg.
R
Respiratory quotient, often assumed to be 0.8.
FiO₂
Inspired oxygen fraction.

At sea level on room air, with PaCO₂ 40 and R 0.8: 0.21 × (760 − 47) − 40 / 0.8 ≈ 100 mmHg.

Compares calculated alveolar oxygen with measured arterial oxygen.

Expected values depend on age and inspired oxygen. Keep PAO₂ and PaO₂ distinct.

Units & worked example
PAO₂
Calculated alveolar oxygen pressure, mmHg.
PaO₂
Measured arterial oxygen pressure, mmHg.

PAO₂ 100 mmHg and PaO₂ 70 mmHg: 100 − 70 = 30 mmHg.

Adds oxygen bound to hemoglobin and oxygen dissolved in blood.

1.34 is a common teaching coefficient; some references use another value. Abnormal hemoglobins require co-oximetry and more careful interpretation.

Units & worked example
CaO₂
Oxygen content, mL O₂/dL blood.
Hb
Hemoglobin, g/dL.
SaO₂
Arterial oxygen saturation as a fraction, not a percent.
PaO₂
Arterial oxygen pressure, mmHg.

Hb 12, SaO₂ 0.95, PaO₂ 80: (1.34 × 12 × 0.95) + (0.003 × 80) ≈ 15.52 mL O₂/dL.

Ventilation

Minute volume, alveolar ventilation, and dead space.

Total volume moved per minute.

Convert mL to L when reporting L/min. Minute ventilation includes dead-space ventilation.

Units & worked example
V̇E
Minute ventilation, L/min.
VT
Tidal volume, L/breath.
f
Respiratory frequency, breaths/min.

VT 0.45 L and f 16/min: 0.45 × 16 = 7.2 L/min.

Volume per minute available for gas exchange.

Use the same volume units for VT and VD. Dead-space volume is not fixed across patients.

Units & worked example
V̇A
Alveolar ventilation, L/min.
VT, VD
Tidal volume and physiologic dead-space volume per breath, both in L.
f
Respiratory frequency, breaths/min.

VT 0.45 L, VD 0.15 L, f 16/min: (0.45 − 0.15) × 16 = 4.8 L/min.

Uses arterial and mixed-expired CO₂ to estimate wasted ventilation.

PĒCO₂ is not end-tidal CO₂. Enghoff also reflects shunt and V/Q abnormalities; it is not a pure measurement of dead space.

Units & worked example
VD/VT
Dimensionless fraction; multiply by 100 for percent.
PaCO₂
Arterial CO₂ pressure.
PĒCO₂
Mixed-expired, volume-averaged CO₂ pressure; use the same pressure units.

PaCO₂ 40 and mixed-expired PCO₂ 28 mmHg: (40 − 28) / 40 = 0.30, or 30%.

Relates breathing frequency to spontaneous tidal volume.

Use liters. AARC 2024 suggests RSBI is not needed to determine adult SBT readiness; it is not a stand-alone extubation rule.

Units & worked example
f
Respiratory frequency, breaths/min.
VT
Spontaneous tidal volume in liters.
RSBI
Reported in breaths/min/L.

f 24/min and VT 0.30 L: 24 / 0.30 = 80 breaths/min/L.

Ventilator mechanics

Pressure, resistance, compliance, and predicted body weight.

Volume change per unit of elastic driving pressure.

Requires passive conditions and valid holds without a significant leak. This describes lungs plus chest wall, not lung compliance alone.

Units & worked example
VT
Tidal volume, mL.
Pplat
Plateau pressure during a valid no-flow hold, cm H₂O.
PEEPtotal
Total PEEP, including intrinsic PEEP, cm H₂O.
Cstat
Respiratory-system compliance, mL/cm H₂O.

VT 450 mL, Pplat 25, total PEEP 10: 450 / (25 − 10) = 30 mL/cm H₂O.

A bedside volume-to-pressure estimate during airflow.

Uses total PEEP as the baseline here. Flow resistance affects this estimate; it does not replace static compliance.

Units & worked example
VT
Tidal volume, mL.
PIP
Peak inspiratory pressure, cm H₂O.
PEEPtotal
Total end-expiratory pressure used as the baseline here, cm H₂O.
Cdyn
Dynamic estimate, mL/cm H₂O.

VT 450 mL, PIP 35, total PEEP 10: 450 / (35 − 10) = 18 mL/cm H₂O.

Uses the resistive pressure drop during constant-flow ventilation.

Requires passive ventilation, constant flow, and a valid plateau. Do not substitute peak flow from a decelerating waveform. Includes artificial-airway resistance.

Units & worked example
PIP, Pplat
Peak and plateau pressures, cm H₂O.
flow
Constant inspiratory flow, L/s. Divide L/min by 60.
R
Resistance, cm H₂O·s/L.

PIP 35, Pplat 25, flow 0.50 L/s: (35 − 25) / 0.50 = 20 cm H₂O·s/L.

Pressure needed to deliver a tidal volume above the end-expiratory baseline.

Use a valid plateau measurement, not PIP. Respiratory-system driving pressure differs from transpulmonary driving pressure.

Units & worked example
Pplat
Plateau pressure, cm H₂O.
PEEPtotal
Applied plus intrinsic PEEP, cm H₂O.
ΔP
Respiratory-system driving pressure, cm H₂O.

Pplat 25 and total PEEP 10: 25 − 10 = 15 cm H₂O.

Describes the speed of volume change in a single-compartment model.

About 63% of the volume change occurs in one time constant and 95% in three. Inspiratory measurements can underestimate expiratory emptying time when expiratory resistance is higher.

Units & worked example
R
Resistance, cm H₂O·s/L.
C
Compliance, L/cm H₂O; divide mL/cm H₂O by 1,000.
τ
Time constant, seconds.

R 10 cm H₂O·s/L and C 0.05 L/cm H₂O: 10 × 0.05 = 0.50 seconds.

Adult ARDS Network height-based equations used for ventilator tidal-volume calculations.

These are the adult protocol's sex-specific equations. Use height, not actual body weight. They are not pediatric formulas.

Units & worked example
PBW
Predicted body weight, kg.
height
Height in inches. To convert cm to inches, divide by 2.54.

At 70 inches: male PBW = 50 + 2.3 × 10 = 73 kg; female PBW = 68.5 kg.

Pulmonary function

Lung capacities, spirometry, and bronchodilator response.

Capacities combine the individual lung volumes.

Spirometry alone cannot measure RV, FRC, or TLC. These require an additional lung-volume measurement method.

Units & worked example
VT
Tidal volume.
IRV, ERV
Inspiratory and expiratory reserve volumes.
RV
Residual volume after maximal expiration.
IC, VC
Inspiratory capacity and vital capacity.
FRC, TLC
Functional residual capacity and total lung capacity. Use L throughout.

IRV 2.5 L, VT 0.5 L, ERV 1.0 L, RV 1.5 L: IC 3.0 L, VC 4.0 L, FRC 2.5 L, TLC 5.5 L.

Fraction of the forced vital capacity exhaled in the first second.

A ratio of 0.625 and 62.5% mean the same thing. Interpret against appropriate reference limits and test quality.

Units & worked example
FEV1
Forced expiratory volume in one second, L.
FVC
Forced vital capacity, L.

FEV1 2.0 L and FVC 3.2 L: (2.0 / 3.2) × 100 = 62.5%.

Change in FEV1 or FVC as a percentage of its predicted value.

The 2022 ERS/ATS criterion is greater than 10% of predicted in FEV1 or FVC. This uses predicted, not baseline, as the denominator.

Units & worked example
pre, post
Volumes before and after bronchodilator, both FEV1 or both FVC.
predicted
Predicted value for that same measurement, in matching volume units.

FEV1 increases from 2.0 to 2.3 L; predicted FEV1 is 3.5 L: 100 × 0.3 / 3.5 ≈ 8.6% of predicted.

Acid–base

pH, anion gap, and expected respiratory compensation.

Relates pH to the bicarbonate–CO₂ buffer system.

Keep the entire denominator in parentheses. This relationship does not identify the primary disorder by itself.

Units & worked example
HCO₃⁻
Bicarbonate, mEq/L or mmol/L.
PaCO₂
Arterial CO₂ pressure, mmHg.
log₁₀
Base-ten logarithm; constants are for approximately 37°C.

HCO₃⁻ 24 and PaCO₂ 40: 6.1 + log₁₀[24 / (0.03 × 40)] ≈ 7.40.

Calculates the gap between routinely measured plasma cations and anions.

Compare with the laboratory's reference interval. Some formulas include potassium; those use a different reference range.

Units & worked example
Na⁺, Cl⁻, HCO₃⁻
Sodium, chloride, and bicarbonate, all in mEq/L.
AG
Anion gap, mEq/L; potassium is omitted in this convention.

Na⁺ 140, Cl⁻ 104, HCO₃⁻ 20: 140 − (104 + 20) = 16 mEq/L.

Adjusts the observed gap for reduced albumin, using 4.0 g/dL as the reference here.

This is an estimate. If albumin is reported in g/L, convert to g/dL by dividing by 10 before using this version.

Units & worked example
AG
Observed anion gap, mEq/L.
albumin
Serum albumin, g/dL; not g/L.

AG 12 and albumin 2.0 g/dL: 12 + 2.5 × (4.0 − 2.0) = 17 mEq/L.

Estimates respiratory compensation for a primary metabolic acidosis.

Use only for metabolic acidosis. A measured PaCO₂ outside the expected range suggests an additional respiratory disorder.

Units & worked example
HCO₃⁻
Bicarbonate, mEq/L.
Expected PaCO₂
Expected arterial CO₂ pressure, mmHg.

HCO₃⁻ 16: (1.5 × 16) + 8 = 32 ± 2 mmHg, or 30–34 mmHg.

Circulation & oxygen delivery

Cardiac output, blood pressure, vascular resistance, and oxygen transport.

Volume pumped by the heart each minute.

HR × SV gives mL/min when SV is in mL. Divide by 1,000 to report L/min.

Units & worked example
HR
Heart rate, beats/min.
SV
Stroke volume, mL/beat.
CO
Cardiac output, L/min.

HR 90 and SV 60 mL: (90 × 60) / 1,000 = 5.4 L/min.

Indexes cardiac output to body surface area.

Use L/min for CO and m² for BSA.

Units & worked example
CO
Cardiac output, L/min.
BSA
Body surface area, m².
CI
Cardiac index, L/min/m².

CO 5.4 L/min and BSA 1.8 m²: 5.4 / 1.8 = 3.0 L/min/m².

Estimates average systemic arterial pressure during the cardiac cycle.

This is an approximation, especially when heart rate or waveform shape is abnormal. MAP here is not mean airway pressure.

Units & worked example
SBP, DBP
Systolic and diastolic blood pressures, mmHg.
MAP
Mean arterial pressure, mmHg.

Blood pressure 120/60 mmHg: (120 + 2 × 60) / 3 = 80 mmHg.

Relates the systemic vascular pressure gradient to blood flow.

The factor 80 converts mmHg·min/L to dyn·s/cm⁵. CVP is used as an estimate of right atrial pressure.

Units & worked example
MAP, CVP
Mean arterial and central venous pressures, mmHg.
CO
Cardiac output, L/min.
SVR
Resistance, dyn·s/cm⁵.

MAP 80, CVP 5, CO 5 L/min: 80 × (80 − 5) / 5 = 1,200 dyn·s/cm⁵.

Amount of oxygen delivered to the systemic circulation each minute.

The factor 10 converts L of blood to dL. Delivery is not the same as oxygen consumption.

Units & worked example
CO
Cardiac output, L/min.
CaO₂
Arterial oxygen content, mL O₂/dL.
ḊO₂
Oxygen delivery, mL O₂/min.

CO 5 L/min and CaO₂ 18 mL O₂/dL: 5 × 18 × 10 = 900 mL O₂/min.

Sources

Equations and conventions checked October 28, 2026. Examples use invented study values.

  1. Hess, et al. Respiratory Care: Principles and Practice, 3rd ed. Equations appendix.
  2. OpenAnesthesia / IARS. Oxygen Physiology. 2024.
  3. Comparison of non-invasive to invasive oxygenation ratios: prospective cohort study. 2018.
  4. The PICU Handbook. Respiratory Formulas and Parameters. McGraw Hill.
  5. Doorduin, et al. Assessment of dead-space ventilation in ARDS: a prospective observational study. 2016.
  6. AARC. Spontaneous Breathing Trials for Liberation From Adult Mechanical Ventilation. 2024.
  7. Walter, Corbridge, and Singer. Invasive Mechanical Ventilation. Northwestern University teaching resource.
  8. AARC. Patient–Ventilator Assessment. 2024.
  9. Hess and Kacmarek. Essentials of Mechanical Ventilation. Time constants. McGraw Hill.
  10. NHLBI ARDS Network. FACTT trial protocol: predicted body weight equations.
  11. ERS/ATS. Standardisation of the measurement of lung volumes, 2023 update.
  12. ATS/ERS. Standardization of Spirometry, 2019 Update.
  13. ERS/ATS. Interpretive strategies for routine lung function tests. 2022.
  14. American Thoracic Society. Interpretation of ABGs.
  15. Figge, et al. Anion gap and hypoalbuminemia. Original observational study. 1998.
  16. OpenAnesthesia / IARS. Calculation of Pulmonary and Systemic Vascular Resistance. 2026.
  17. Song, et al. Cardiac structure and function in humans: a cardiovascular physiology laboratory. 2009.
  18. OpenAnesthesia / IARS. Gas Equations. 2026.
  19. Suarez, Bukowski, and Hankins. Hemodynamic Monitoring of the Critically Ill Patient. GLOWM.
  20. Keller, et al. How I Teach Auto-PEEP: Applying the Physiology of Expiration. ATS Scholar. 2022.
Back to top ↑